HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual page 200

Edge switch 2/24 service manual
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Messages
Message
Date entered is
invalid.
Device applications
should be terminated
before starting
diagnostics. Press
NEXT to continue.
[device WWN] cannot
be removed from the
Switch Membership
List while
participating in
Switch Binding. The
device must be
isolated from the
switch, or Switch
Binding deactivated
before it can be
removed.
Disabling Insistent
Domain ID will
disable Fabric
Binding. Do you want
to continue?
A–30
Description
The date is entered
incorrectly at the
Configure Date and
Time dialog box.
Individual field entries
may be correct, but
the overall date is
invalid (for example, a
day entry of 31 for a
30-day month).
Port diagnostics
(loopback tests)
cannot be performed
on a port while an
attached device
application is
running.
A user attempted to
remove a device
WWN from the switch
membership list
(SANtegrity feature)
with switch binding
enabled.
Fabric binding is
enabled through the
HAFM application
and a user attempted
to disable the
Insistent Domain ID
parameter at the
Configure Switch
Parameters dialog
box.
Action
Verify each entry is valid and
consistent.
Terminate the device
application and perform
diagnostics again.
Disconnect the device by
blocking the switch port and
setting the switch offline, or
disable switch binding
through the Switch Binding
Change State dialog box
before removing devices from
the switch membership list.
Click Yes to continue and
disable fabric binding.
edge switch 2/24 service manual

Advertisement

Table of Contents
loading

Table of Contents