Diagnostics
Table 2–11: Port Operational and LED States (Continued)
Operational
State
Link Incident
Segmented
E_Port
12
A link incident may have occurred, but the LIN alerts option is not enabled for the port
and the attention indicator does not appear.
At the Hardware View, click Logs and select Link Incident Log. The Link Incident
Log displays. If a link incident occurred, the affected port number is listed with one of
the following messages.
Link interface incident - implicit incident.
Link interface incident - bit-error threshold exceeded.
Link failure - loss of signal or loss of synchronization.
Link failure - not-operational primitive sequence (NOS)
received.
Link failure - primitive sequence timeout.
Link failure - invalid primitive sequence received for the
current link state.
Did one of the listed messages appear in the Link Incident Log?
YES
NO
The switch appears operational. Exit MAP.
Go to
step
25.
2–68
Green
Amber
LED
LED
Off
Off
On
Off
Action
Go to
step
25.
MAP
0700.
Go to
edge switch 2/24 service manual