Event Codes
Message:
SFP optical transceiver hot-insertion initiated.
Severity:
Informational.
Explanation:
Installation of a small form factor pluggable (SFP) optical transceiver was initiated with
the switch powered on and operational. The event indicates that operational firmware
detected the presence of the transceiver.
Action:
No action required.
Event Data:
Byte 0 = port number (00 through 23).
Bytes 4 through 7 = elapsed millisecond tick count.
Distribution:
Switch
EWS
Event
Log
Message:
SFP optical transceiver nonfatal error.
Severity:
Minor.
Explanation:
Switch firmware detected an SFP optical transceiver non-fatal error.
Action:
Replace the failed transceiver with a functional transceiver of the same type.
Event Data:
Byte 0 = port number (00 through 23).
Byte 1 = engineering reason code.
Bytes 4 through 7 = elapsed millisecond tick count.
Distribution:
Switch
EWS
Event
Log