Diagnostics
9
A minor error occurred that caused fabric controller database to be re-initialized to an
empty state. As a result, the switch briefly lost interswitch link capability. The following
explains the error.
Event code 061 - The fabric controller database failed CRC validation.
All interswitch links resume operation after CTP reset. Perform the data collection
procedure and return the Zip disk to HP for analysis. Exit MAP.
10
As indicated by an event code 062, the fabric controller software detected a path to
another switch (or fabric element) in a multiswitch fabric that traverses more than three
interswitch links (hops). Fibre Channel frames may persist in the fabric longer than
timeout values allow.
Advise the customer of the problem and work with the system administrator to
reconfigure the fabric so the path between any two fabric elements does not traverse
more than three hops.
Did fabric reconfiguration solve the problem?
NO
YES
The switch and multiswitch fabric appear operational.
Exit MAP.
Contact the next level of support. Exit MAP.
11
As indicated by an event code 063, the fabric controller software detected a fabric
element (switch or switch) in a multiswitch fabric that has more than 32 ISLs attached.
Fibre Channel frames may be lost or routed in loops because of potential fabric
routing problems.
Advise the customer of the problem and work with the system administrator to
reconfigure the fabric so that no switch or switch elements have more than 32 ISLs.
Did fabric reconfiguration solve the problem?
NO
YES
The switch and multiswitch fabric appear operational.
Exit MAP.