Table 3–2: Port Operational States (Continued)
Port
Blue/Green
State
LED
Not
Off
Operati
onal
Port
Off
Failure
Segme
On
nted
E_Port
Testing
Off
On

Hardware View

The Hardware View
information about a specified switch. This information is useful to maintenance
personnel for port-specific fault isolation and repair verification, link incidents, and
port segmentation problems.
Port operational state information from the Port Properties dialog box
(Figure
3–8).
Port LED behavior that emulates the operational status of the corresponding real
switch. Refer to the hp StorageWorks edge switch 2/24 installation guide for
explanation of LED behavior.
Colored alert symbols (yellow triangle or red diamond with yellow background)
that indicate port status. Refer to the hp StorageWorks edge switch 2/24 product
manager user guide for an explanation of alert symbol indications.
edge switch 2/24 service manual
Amber
Alert
LED
Symbol
Off
Yellow
Triangle
On
Red and
Yellow
Blinking
Diamond
Off
Yellow
Triangle
Blinking
Yellow
Triangle
Blinking
Yellow
Triangle
(Figure
3–7) displays a representation of and associated
Description
The port is receiving the not
operational sequence (NOS) from an
attached device.
The port failed and requires service.
The E_Port is segmented, preventing
two connected switches from joining
and forming a multiswitch fabric.The
reason appears in the Reason field of
the Port Properties dialog box.
The port is performing an internal
loopback test.
The port is performing an external
loopback test.
Repair Information