Table 2–3: Event Codes versus Maintenance Action (Continued)
Event
Code
070
E_Port is segmented.
071
Switch is isolated.
072
E_Port connected to unsupported switch.
073
Fabric initialization error.
074
ILS frame delivery error threshold
exceeded.
080
Unauthorized worldwide name.
081
Invalid attachment.
120
Error while processing system
management command.
121
Zone set activation failed - zone set too
large.
200
Power supply AC voltage failure.
201
Power supply DC voltage failure.
203
Power supply AC voltage recovery.
204
Power supply DC voltage recovery.
206
Power supply removed.
207
Power supply installed.
300
Cooling fan propeller failed.
301
Cooling fan propeller failed.
302
Cooling fan propeller failed.
303
Cooling fan propeller failed.
304
Cooling fan propeller failed.
305
Cooling fan propeller failed.
310
Cooling fan propeller recovered.
311
Cooling fan propeller recovered.
312
Cooling fan propeller recovered.
edge switch 2/24 service manual
Explanation
Diagnostics
Action
MAP
0700.
Go to
MAP
0700.
Go to
MAP
0700.
Go to
Refer to
Collecting
Maintenance Data on page
3–22.
Refer to
Collecting
Maintenance Data on page
3–22.
MAP
0600.
Go to
MAP 0600
Go to
MAP 0600
Go to
Reduce size of zone set
and retry.
MAP
0100.
Go to
MAP
0100.
Go to
No action required.
No action required.
Replace FRU.
No action required.
MAP
0500.
Go to
MAP
0500.
Go to
MAP
0500.
Go to
MAP
0500.
Go to
MAP
0500.
Go to
MAP
0500.
Go to
No action required.
No action required.
No action required.
2–3