Send Firmware Confirmation Dialog Box - HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual

Edge switch 2/24 service manual
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Repair Information
3. Before downloading firmware version XX.YY.ZZ to a switch, ensure version
XX.YY.ZZ or higher of the HAFM application is running on the HAFM server.
a. Select About from the Help menu. The About dialog box displays the HAFM
application version. Click OK to close the dialog box.
b. If required, install the correct version of the HAFM application
Upgrade Software on page
4. Select the icon representing the switch for which a firmware version is to be
downloaded. The Hardware View for the selected switch displays.
5. As a precaution to preserve switch configuration information, perform the data
collection procedure
6. At the navigation control panel, select Firmware Library from the Maintenance
menu. The Firmware Library dialog box displays.
7. Select the firmware version to be downloaded and click Send. The send function
verifies existence of certain switch conditions before the download begins. If an
error occurs, a message displays indicating the problem must be fixed before the
firmware download. Conditions that terminate the process include:
— The firmware version is being installed to the switch by another user.
— The switch-to-HAFM server link fails or times out.
If a problem occurs and a corresponding message displays, go to
MAP on page 2–6
confirmation box displays.
Figure 3–22: Send Firmware confirmation dialog box
8. Click Yes. The Send Firmware dialog box displays.
3–36
3–42).
(Collecting Maintenance Data on page
to isolate the problem. If no error occurs, the Send Firmware
(Install or
3–22).
MAP 0000: Start
edge switch 2/24 service manual