Diagnostics
Was a corrective action performed?
YES
NO
Go to
4
Verify redundant power supply operation.
a. Inspect the power supply and ensure all amber LEDs are extinguished.
b. At the Hardware View, observe the graphic representing the power supply and
ensure a failure symbol (blinking red and yellow diamond) does not appear.
Is a failure indicated?
YES
NO
The switch appears operational. Exit MAP.
5
Ensure the indicated power supply is correctly installed and seated in the switch. If
required, partially remove and reseat the power supply.
Was a corrective action performed?
YES
NO
Go to
6
Verify redundant power supply operation.
a. Inspect the power supply and verify all amber LEDs are extinguished.
b. At the Hardware View, observe the graphic representing the power supply and
ensure a failure symbol (blinking red and yellow diamond) does not appear.
Is a failure indicated?
YES
NO
The switch appears operational. Exit MAP.
2–28
step
5.
step
7.
edge switch 2/24 service manual