Event Codes
Message:
Cooling fan propeller failed.
Severity:
Major.
Explanation:
Three cooling fans (out of six) failed or are rotating at insufficient angular velocity. The
remaining fans are operational. The amber LED illuminates at the rear of the power
supply assembly (or assemblies) associated with the failed fans.
Action:
Replace the power supply assembly (or assemblies) containing the indicated fan
modules.
Event Data:
The first byte of event data (byte 0) specifies the failed fan numbers (0 through 5
inclusive).
Distribution:
Switch
EWS
Event
Log
Message:
Cooling fan propeller failed.
Severity:
Major.
Explanation:
Four cooling fans (out of six) failed or are rotating at insufficient angular velocity. The
remaining fans are operational. The amber LED illuminates at the rear of both power
supply assemblies.
Action:
Replace both power supply assemblies.
Event Data:
The first byte of event data (byte 0) specifies the failed fan numbers (0 through 5
inclusive).
Distribution:
Switch
EWS
Event
Log
B–22
Event Code: 302
HAFM Server
System
Event
Error
Log
LED
Event Code: 303
HAFM Server
System
Event
Error
Log
LED
E-Mail
Call
Home
E-Mail
Call
Home
edge switch 2/24 service manual
Host
Sense
Link
Info
Incident
Host
Sense
Link
Info
Incident

Advertisement

   Related Manuals for HP 316095-B21 - StorageWorks Edge Switch 2/24

Comments to this Manuals

Symbols: 0
Latest comments: