Message:
Fabric Controller database invalid.
Severity:
Minor.
Explanation:
Following an IML, or firmware download, the Fabric Controller database failed its CRC
validation. All Fabric Controller databases are initialized to an empty state, resulting in a
momentary loss of interswitch communication capability.
Action:
Perform the data collection procedure and return the Zip disk to Hewlett-Packard
support personnel.
Event Data:
No supplementary data included with this event.
Distribution:
Switch
EWS
Event
Log
Message:
Maximum interswitch hop count exceeded.
Severity:
Informational.
Explanation:
The fabric controller software detected that a path to another fabric element (Director or
Edge Switch) traverses more than seven interswitch links (ISLs or hops). This may result
in Fibre Channel frames persisting in the fabric longer than standard timeout values
allow.
Action:
If possible, reconfigure the fabric so the path between any two Director or Edge Switch
traverses no more than seven ISLs.
Event Data:
Byte 0 = domain ID of the fabric element (director or switch) more than seven hops
away.
Bytes 1 - 3 = reserved.
Distribution:
Switch
EWS
Event
Log
edge switch 2/24 service manual
Event Code: 061
HAFM Server
System
Event
Error
Log
LED
Event Code: 062
HAFM Server
System
Event
Error
Log
LED
E-Mail
Call
Home
E-Mail
Call
Home
Event Codes
Host
Sense
Link
Info
Incident
Host
Sense
Link
Info
Incident
B–7

Advertisement

   Related Manuals for HP 316095-B21 - StorageWorks Edge Switch 2/24

Comments to this Manuals

Symbols: 0
Latest comments: