Power Supply Events (200 Through 299 - HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual

Edge switch 2/24 service manual
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Event Codes

Power Supply Events (200 through 299)

Message:
Power supply AC voltage failure.
Severity:
Major.
Explanation:
Alternating current (AC) input to the indicated power supply is disconnected or AC
circuitry in the power supply failed. The second power supply assumes the full operating
load for the switch.
Action:
Ensure the power supply is connected to facility AC power, and verify operation of the
facility power source. If the AC voltage does not recover (indicated by event code 203),
replace the failed power supply. Perform the data collection procedure and return the Zip
disk and failed power supply to Hewlett-Packard support personnel.
Event Data:
No supplementary data included with this event.
Distribution:
Switch
EWS
Event
Log
Message:
Power supply DC voltage failure.
Severity:
Major.
Explanation:
Direct current (DC) circuitry in the power supply failed. The second power supply
assumes the full operating load for the switch.
Action:
Replace the failed power supply. Perform the data collection procedure and return the
Zip disk and failed power supply to Hewlett-Packard support personnel.
Event Data:
No supplementary data included with this event.
Distribution:
Switch
EWS
Event
Log
B–18
Event Code: 200
HAFM Server
System
Event
Error
Log
LED
Event Code: 201
HAFM Server
System
Event
Error
Log
LED
E-Mail
Call
Home
E-Mail
Call
Home
edge switch 2/24 service manual
Host
Sense
Link
Info
Incident
Host
Sense
Link
Info
Incident

Advertisement

Table of Contents
loading

Table of Contents