HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual page 100

Edge switch 2/24 service manual
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Diagnostics
Table 2–14: MAP 600: Event Codes (Continued)
Event
Code
071
072
3
Is fault isolation being performed at the HAFM server (or customer-supplied server)?
YES
NO
Fault isolation is being performed through the EWS interface. Go to
4
Does a yellow triangle (attention indicator) appear adjacent to a Fibre Channel port
graphic at the Hardware View?
YES
NO
The problem is transient and the switch-to-fabric element connection appears
operational. Exit MAP.
5
Inspect the port state and LED status for all ports with an attention indicator.
a. At the Hardware View, double-click the port graphic with the attention indicator.
The Port Properties dialog box displays.
b. Inspect the Operational State field at the Port Properties dialog box.
Does the Operational State field indicate Segmented E_Port?
YES
NO
Analysis for other link incident is not described in this MAP. Go to
Port Failure and Link Incident Analysis on page
2–80
Explanation
switch is isolated.
E_Port connected to unsupported switch.
Action
Go to
step
12.
Go to
step
13.
step
MAP 0600:
2–64. Exit MAP.
edge switch 2/24 service manual