Juniper JUNOSE 11.2.X BGP AND MPLS Configuration Manual page 707

For e series broadband services routers - bgp and mpls configuration
Table of Contents

Advertisement

DN = VC Down because Remote PE Unreachable
LD = Local Site Down
RD = Remote Site Down
AS = Max BGP AS path length exceeded
OL = No Out Label
CM = Control Word Mismatch
LN = Local Site not Designated
RN = Remote Site not Designated
Local
Remote
Site
Site
State
-----
------
-----
1
2
UP
L2VPN: l2vpn2
Encapsulation Type ATM AAL5 SDU VCC transport
Use of control word is preferred
Send sequence numbers
Route Distinguisher 100:12
Site Range 20
Sites:
Site Name boston Site Id 3
Multi-homed:
Site-Priority:
Route Target: RT:100:2 both
Interface
Local-Site-Id
----------
-------------
ATM2/0.122
1
ATM2/0.123
1
ATM2/0.124
3
ATM2/0.121
3
Connections status code:
UP = Operational
SC = Local and Remote Site Identifier Collision
EM = Encapsulation Mismatch
OR = Out of Range
DN = VC Down because Remote PE Unreachable
LD = Local Site Down
RD = Remote Site Down
AS = Max BGP AS path length exceeded
OL = No Out Label
CM = Control Word Mismatch
LN = Local Site not Designated
RN = Remote Site not Designated
Local
Remote
Site
Site
State
-----
------
-----
1
2
UP
1
3
UP
3
1
UP
3
2
UP
Copyright © 2010, Juniper Networks, Inc.
Remote
PE
In-label
Out-label
-------
--------
---------
2.2.2.2
25
74
Yes
100
Route Targets:
Admin
Remote-Site-Id
state
--------------
-------
2
enabled
3
enabled
1
enabled
2
enabled
Remote
PE
In-label
-------
-------------
2.2.2.2
35
implicit-null
implicit-null
2.2.2.2
55
To display detailed information about connections for a specific VPWS instance:
host1#show l2vpn connections instance l2vpn1 details
L2VPN: l2vpn1
Encapsulation Type ATM AAL5 SDU VCC transport
Use of control word is preferred
Send sequence numbers
Route Distinguisher 100:11
MPLS
Up-down
NH Idx
Time
--------
--------
0000001d
01:49:12
Oper
state
-----
up
up
up
up
MPLS
Out-label
NH Idx
-------------
--------
84
0000001d
implicit-null
2d000008
implicit-null
2d000007
86
0000001d
Chapter 16: Monitoring VPWS
Up-down
Time
--------
01:50:40
02:24:45
02:24:45
01:50:40
671

Advertisement

Table of Contents
loading

This manual is also suitable for:

Junose 11.2.x

Table of Contents