Chapter 2 Principles of Operation
2.4.08 DC Fan
The fan is controlled by the FAN ON-P signal from the PCNT-150 board. In order for the
facsimiles printer to operate, the signal FAN SENSE-N must be active.
NOTE:
The fuser and the fan are not enabled when the cover is open. If the fan fails to run, the fuser will
turn off and the message PRINTER ALARM 4 will be displayed. Printing is disabled.