3.2.36 Scanner Frame Assembly
CAUTION:
Use extreme caution when removing the scanner frame assembly.
The speaker cable is routed through a hole in the scanner frame.
The LED cable and stepper motor cables are clamped to the scanner frame assembly. Release
these cables before removing the frame.
Detach the connector from the transmit stepper motor before removing the scanner frame. The
connector may be accessed from within the frame.
1. Perform these procedures:
3.2.01
3.2.03
3.2.04
3.2.05
3.2.09
3.2.15
3.2.16
3.2.17
3.2.20
3.2.21
2. Remove the six screws (1).
3. Remove the scan frame assembly (2).
P/N N/A Screw
RSPL B.2.10
P/N 53343501 Frame: Scanner Assembly
P/N 50104401 Frame: Scanner
Service Guide OF1000
Chapter 3 Maintenance & Disassembly
RSPL B.2.10
RSPL B.2.13
Page: 102