3.2.19 Separation Rubber Assembly
1. Power OFF the unit and detach the AC power cord.
2. Open the control panel unit (1).
3. Remove the separation rubber assembly (2) by lifting the assembly from its mounting hooks.
NOTE:
The separation rubber assembly includes the separation rubber, the separation mylar,
and the 10 x 40 mm tape. To replace any of these parts, order the assembly.
Cleaning
Clean the assembly as necessary. Use a soft cloth and water to clean.
this Service Handbook for cleaning details
Replacement
Replace the assembly when it becomes worn.
P/N 53344901 Assembly: Separation Rubber
P/N N/A Rubber: Separation
P/N N/A Mylar: Separation
P/N N/A Tape (10 x 40 mm)
RSPL B.2.14
RSPL B.2.14
RSPL B.2.14
RSPL B.2.14
Service Guide OF1000
Chapter 3 Maintenance & Disassembly
Refer to Section 3.4 of
.
Page: 85