4.6.05 High-Speed Modem Transmit Test

This test must be run in conjunction with an Okifax 1000 at a remote location. The remote Okifax
1000 must be set up to run the High Speed Modem Receive Test.
High-Speed Modem Test should fail.
Procedure
1. Press
SELECT FUNCTION.
2. Press
COPY
twice.
3. Press
LEFT ARROW
4. Press the
"5"
Key on the ten-key pad.
5. Press
LEFT ARROW.
The following message will be displayed.
H-M/D SEND TEST
9600 01 38" 0000
Where:
9600: Data Transfer Rate
01 38" : Transmission Time in Minutes ( ' ) and Seconds ( " )
0000: Data Transfer Error Counter
6. Press
STOP
four times to exit the test.
Copyright 1997, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA Business
Partner Exchange (BPX) for any updates to this material. (http://bpx.okidata.com)
twice.
Service Guide OF1000
Chapter 4 Failure & Repair Analysis