Rap 13: Multi-Frequency Tone Test Failure - OKIDATA OF1000 Service Manual

Facsimile product
Table of Contents

Advertisement

RAP 13: Multi-Frequency Tone Test Failure

START
Do all keys of the ten-key pad fail to generate a tone?
NO Replace the OPE-150 board.
Is the problem resolved?
NO Replace the MCNT-150 board.
YES End of procedure.
YES Is the monitor volume (USER FUNCTION #5) adjusted so the
NO Modify User Function #5.
Copyright 1997, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA Business
Partner Exchange (BPX) for any updates to this material. (http://bpx.okidata.com)
tones will be audible?
YES Is CN11 (speaker harness) connected to CN11 of the
MCNT-150?
NO Connect it.
YES Replace the MCNT-150
Service Guide OF1000