3.2.39 Registration and Main Stepper Motors

1. Perform these procedures:
3.2.01
3.2.05
3.2.15
3.2.16
2. Cut the ty-wrap to release the cables.
3. Remove the two screws (1).
4. Carefully work the cables from the frame.
5. Remove the registration stepper motor (2).
6. Remove the two screws (3).
7. Carefully work the cables from the frame.
8. Remove the main stepper motor (4).
NOTES:
Lubrication
Lightly lubricate the gears of the motors.
lubrication details
P/N N/A Screw
RSPL B.2.04
P/N 56510702 Motor: Registration Stepper
P/N 56510703 Motor: Main Stepper
Refer to Section 3.5 of this Service Handbook for
.
B.2.05
B.2.05
Service Guide OF1000
Chapter 3 Maintenance & Disassembly
, B.2.17
, B.2.17