Advertisement

4.6.06 High-Speed Modem Receive Test

This test must be run in conjunction with an Okifax 1000 at a remote location. The remote Okifax 1000
must be set up to run the High Speed Modem Transmit Test.
Modem Test should fail.
Procedure
1. Press
SELECT FUNCTION.
2. Press
COPY
twice.
3. Press
LEFT ARROW
4. Press the
"6"
Key on the ten-key pad.
5. Press
LEFT ARROW.
The following message will be displayed.
H-M/D REC. TEST
9600 01 38" 0000
Where:
9600: Data Transfer Rate
01 38" : Transmission Time in Minutes (') and Seconds (")
0000: Data Transfer Error Counter
6. Press
STOP
four times to exit the test.
twice.
Service Guide OF1000
Chapter 4 Failure & Repair Analysis
Refer to RAP 12
Page: 175
if the High-Speed