Protocol Dump - OKIDATA OF1000 Service Manual

Facsimile product
Table of Contents

Advertisement

4.7.02 Protocol Dump

The Protocol Dump Report provides the service technician with a tool to analyze the control signals of G3
protocol transmissions and receptions. This report can be generated manually or automatically. In either
case, the SERVICE BIT (Technical Function #27) must be ON in order to print this report.
Manual Generation
1. Press
SELECT
FUNCTION.
2. Press
RIGHT
ARROW.
3. Press the
"*"
Key.
4. Press
LEFT ARROW
5. Press
STOP
to exit.
Automatic Generation
1. Press
SELECT FUNCTION.
2. Press
COPY
twice.
3. Press
LEFT ARROW.
4. Press
RIGHT ARROW.
5. Press
LEFT ARROW.
6. Enter
"02".
7. Press
RIGHT ARROW
8. Press
LEFT ARROW
9. Press
SELECT FUNCTION
NOTE:
Once Technical Function #02 is set to ON, a Protocol Dump Report will be generated immediately after
each communication session.
until the desired setting (YES or NO) is selected.
to save the setting.
to exit.
Service Guide OF1000
Chapter 4 Failure & Repair Analysis
Page: 181

Advertisement

Table of Contents
loading

This manual is also suitable for:

Okifax 1000

Table of Contents