RAP 13 Multi-frequency Send Test Failure
START
Detach the phone line from the unit.
Remove the right side and rear covers.
Set up an oscilloscope as listed below.
Set the time / div to .5 ms / division. Set Channel 1 volts / div to .1 volt / division.
Perform MF Send Test.
Place the oscilloscope probe on pin 1 of CN3 on the main control board.
Is a .15 v analog signal present?
YES Replace the speaker.
NO Replace the main control board.
Is the problem resolved?
YES End of procedure.
NO Replace the operator panel assembly.
Is the problem resolved?
YES End of procedure.
NO Contact Okidata Technical Support.
Copyright 1997, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA Business
Partner Exchange (BPX) for any updates to this material. (http://bpx.okidata.com)
Service Guide OF2200/2400/2600
Chapter 2 Failure Analysis
Page: 61