Mounting Stand

Low Label Sensor

The low label sensor activates the warning beacon to alert the operator of a
low label situation. The low label indication can come from the optional fault
warning beacon (light tower), message to the LCD or message to the host
computer. The low label sensor is typically not adjusted after manufacturing
as it is located behind the media unwind assembly. Its position may be moved
to allow more or less media stock on the unwind roll before signal activation.
Proceed as follows:
1. Remove the front label roll retainer and the label roll back stop.
2. Remove the two #6-32 screws, relocate the sensor in one of the three
possible sensor location holes, and replace the #6-32 anchoring screws.
3. Replace the front label roll retainer and the label roll back stop.
A
A
Low Label
Sensor Location
Sensor
Hole
Figure 36. Low Label Sensor Adjustment