Boundary Check
This option turns on or off the page boundary check for all print elements.
Enable (the default). When enabled, an out of bound error is reported if
the print element is out of the page boundary.
Disabled. When disabled, no out of bound error is reported. The out of
bound print element prints over the page boundary.
Repeat Form Opt
Enable (the default). Speeds up the processing of repeated forms for
PGL, thereby resulting in increased printer throughput. This option
provides no speed benefit for forms that are unrelated to one another and
should be disabled under those circumstances.
Disable. Should be selected when subsequent forms are unrelated to
one another.
Preparser Cmd
Allows users to select which preparser command to use. Once the command
is selected, the command will be executed immediately when it is sent to the
printer.
Status (the default). Select (STCC) STATUS command.
Cancel. Select (STCC) CANCEL command.

Preparser Port

Allows users to select which port to send the Preparser command to the
printer.
Disable (the default). Not using the Preparser command.
Parallel. The Parallel port (including attached Ethernet card).
Serial. The Serial port.
Ethernet. The embedded Ethernet port. This option only shows when the
embedded ethernet is installed.
Ret. Status Port
This option selects the port for the Return Status Commands (i.e., ~STATUS
(PGL) and ~HS (PPI/ZGL)) to send the status data back to the Host. The
default is Serial. The remaining options include E-NET Stat Port, E-NET Data
Port for Ethernet connection, and Disable.