Error Report - Printronix SLPA8000 User Manual

Label printer & smart label printer applicator
Table of Contents

Advertisement

Chapter
3
IGP/PGL SETUP
User-Def Ratio
This option allows you to ignore the user-defined barcode ratio and replace it
with the default ratio (X1).
Enable (the default). Allows the user-defined barcode ratio.
Disable. The user-defined barcode ratio will be replaced with the default
ratio (X1).
Lead PDF Dist
Adjusts the leading and trailing character spacing distance of the PDF for
UPC/EAN barcodes.
The range is 0.01- 0.10 inches in 0.01 inch increments, and the factory default
is 0.10 inches.
Trunc Dyn Data
This submenu allows the user to truncate the dynamic data up to the
maximum data length specified in Create Mode.
Disable (the default). If the dynamic data exceeds the maximum data
length, an error will report.
Enable. If the dynamic data exceeds the maximum data length, the data
truncates.

Error Report

This item sets the error reporting capability of the printer for PGL forms as
follows:
On (the default). Full error checking reported. Any element that falls off
the current page is reported as an error.
Debug Mode. Puts the printer in debug mode whenever a form is defined
in CREATE mode. Each line of the CREATE form will be printed along
with an error if one has occurred.
Fault. Allows you to halt the printer if a PGL error occurs. If you select this
option, the PGL error prints on the paper, the message "IGP/PGL Error"
displays on the front panel, and the printer goes offline. You must clear
the error before the printer can resume normal operation.
Off. There is no error checking whatsoever. Graphic elements such as
alpha, line, barcodes, etc. will be clipped if they are beyond the page
boundaries.
142