TROUBLES AND ACTIONS
Control box screen display
Elevation control key
(Left bottom of the main win-
dow)
No GPS localization
(Green) -
Low precisions...
(Orange) -
-
Out of design area...
(Green) Out of design area...
-
3-74
Slope control key
(Right bottom of the main win-
dow)
-
Heading Initializing
-
1.$%
Main causes
Control points file is not
-
yet set.
Positioning accuracy
gets worse than that of
setting in "Machine set-
-
up...". For details, see
"SET FOR CONNECT-
ING TO MACHINE".
Machine direction is not
(Orange)
known.
Project file is not select-
ed.
(Green)
Design surface is not
selected.
Out of range of selected
design surface
(Red)
System error
OPERATION
Remedy
Select the project file in-
cluding control points
file. For details, see
"METHOD FOR IM-
PORTING AND SET-
TING PROJECT
FILES".
Set control points file.
For details, see "METH-
OD FOR IMPORTING
CONTROL POINT
FILES".
Move the machine to a
place under the open
sky, or wait for a better
time for communication
of the GNSS satellite.
When the finishing ac-
curacy is not important,
you may continue the
work.
Move the machine
backward and forward.
Keep the joystick
(steering, directional
and gear shift lever) in
NEUTRAL position
while the machine is
stopped.
Select the project file in-
cluding design surface.
For details, see "METH-
OD FOR IMPORTING
AND SETTING
PROJECT FILES".
Set the design data. For
details, see "METHOD
FOR SELECTING AN
ACTIVE SURFACE
FILE".
Move the machine with-
in the selected range of
design surface.
Take actions according
to other messages dis-
played at the same
time.