Handling Alarm Messages - TESTO 6381 Instruction Manual

Differential pressure transmitter, probes
Hide thumbs Also See for 6381:
Table of Contents

Advertisement

Message
Display
03105
Self-adjustment
error
03106
Adjustment error The adjustment of the
01115
Low adjustment
temperature
01116
High adjustment
temperature
03000
Heat function
defective
4.5.4.

Handling alarm messages

Shown on the
display
New limit value
Scaling changed
Pressure too high
Delta p adjustment
Alarm 1
Alarm 2
Alarm 3
If multiple messages/alarms are activated at the same time, only the last message/alarm is shown. If this is
8
cancelled, the other messages that are still active are no longer displayed.
The message can be assigned the collective alarm function, which means that the collective alarm is activated
9
as soon as at least one of the messages assigned to it is activated. The collective alarm can be assigned to each
of the 4 optional relays. The collective alarm is then always the same, as it can only be defined once.
10
The message is shown upon the occurrence of the event causing the message as well as when closing. Two
entries appear in the history in the P2A software: Message text_start and Message text_end.
Cause
For testo 6615 probe
only: The automatic
self-adjustment was
faulty
probe was faulty
The ambient
temperature is too low
during the pressure
adjustment
The ambient
temperature is too high
during the pressure
adjustment
For testo 6614 probe
only: Heat function
defective
Can be used for
8
collective alarm
Remedying of fault
Contact Testo Service
Contact Testo Service
Take necessary
measures to raise
ambient temperature,
e.g. through heating
Take necessary
measures to lower
ambient temperature,
e.g. through venting.
Contact Testo Service
Additional
9
message end
x
x
x
x
4 Transmitter
10
x
x
x
x
85