7 Parameterizing, adjusting and analyzing software (P2A software)
Field
Unit/analog output
(graphic)
Scale minimum/
maximum
Unit
Signal delay
(graphic)
140
Explanation
Unit: 0 to 1 V/5 V/10 V or 0 to 20 mA/4 to
20 mA.
Vertical: Current version of the analog output
(cannot be changed).
Horizontal: Min./max. scale end points of
selected unit.
The curve changes in accordance with the
entered value of scale minimum and
maximum.
The endpoints of the scaling can be selected
up to the stored scale minimum and
maximum. In the process, scaling can take
place beyond the measuring range in order
to adjust the analog output to the customer
system, see volume 1, 4.2.8. Scaling.
Selection of the physical unit.
When changing the unit, standard values are
set for scale minimum and maximum.
Caution!
When changing the phys. unit, the relay limit
values are set to the assigned default values.
Curve changes according to the set signal
delay.