4 Transmitter
2. Insert screw (4) through hole (3) and screw into rear panel
bracket.
3. Insert probe connector (5) into socket until it engages.
4.3.2.2.
Duct mounting (for testo 6612 probes)
1. Hold wall/duct bracket (order no. 0554 6651) (6) against duct
wall (8) and mark drill holes for wall/duct bracket and probe
shaft.
2. Drill a hole (Ø 12.5 mm) in the duct wall to feed through the
probe shaft.
3. Fasten wall/duct bracket (6) to duct wall with screws (5).
4. Push probe shaft (9) with filter (10) through the middle hole of
the mounting bracket.
24
The wall/duct bracket (6) has an O-ring (7) to seal it against
the duct. Feed the probe shaft (9) carefully through the
wall/duct bracket so that the O-ring is not damaged.