S7200 TV Signal Analyzer Operation Manual
give the viewer a list of what services are available. It is also possible to transmit
a BAT on the same PID, which groups services by type.
(6) SDT_other_error
This check is only performed if the presence of a SDT for other TSs has been
established.
(7) EIT_actual_error
The EIT (Event Information Table) describes what is on now and next on each
service, and optionally details the complete programming schedule. The EIT is
divided into several sub-tables, with only the "present and following" information
for the current TS being mandatory. If there are no 'Present' or 'Following' events,
empty EIT sections will be transmitted according to TR 101 211. The EIT schedule
information is only accessible if the TS is not scrambled.
(8) EIT_other_error
This check is only performed if the presence of an EIT for other TSs has been
established.
(9)EIT_PF_error
If either section ('0' or '1') of each EIT P/F subtable is present both should exist.
Otherwise EIT_PF_error should be indicated.
(10) RST_error
The RST is a quick updating mechanism for the status information carried in the
EIT.