3.4 Connecting the Controller and Sensor Head

3.4.2 Removing the Sensor Head and Sensor Head Connection Cable

1.
Turn the fastening ring on the sensor head connector in the direction of the arrow to loosen
the ring.
2.
Grasp the sensor head connector and pull up to remove.
● When disconnecting, always make sure that the fastening ring has been completely
loosened before pulling out the cable. Risk of damage if you pull the cable with
excessive force (15 N or more) with the fastening ring tightened.
● If changing the type of sensor head to be connected, always switch the power OFF
then ON.

3.4.3 Connecting the Air Tube (Air-Driven Type Only)

1.
While loosening the air tube clamp, slide it from the tip of the air tube and then release it
when it reaches halfway through the tube.
2.
Insert the tip of the air tube until it reaches the root of the joint on the sensor head.
3.
Move the air tube clamp and secure the tip of the air tube.