4.
"SET.2" appears in the digital display / SUB (green). Measure the good workpiece, and
press the ENTER key.
5.
"SET.3" appears in the digital display / SUB (green). Measure the LOW-side defective
workpiece, and press the ENTER key.
6.
When teaching is completed, "GOOD" appears in the digital display / MAIN (white), and the
HIGH set value and LOW set value are finalized. You then return automatically to the base
screen.
● Regardless of the order of steps
values are sorted in order from the highest to the lowest value. The value between the highest
value and the median value is set as the HIGH set value, and the value between the lowest
value and the median value is set as the LOW set value.