5.1 Overview of Setting Menu
Setting item
Number of digits displayed
(DIGIT)
Analog scaling
(ANALOG)
Scaling upper limit value
(ANA.HI)
Scaling lower limit value
(ANA.LO)
Eco mode (ECO)
Alarm delay count
(DELAY)
Pressure check
(PRS.CHK)
Pressure check set value
(PRS.SET)
Catch check
(CAT.CHK)
Number of connected
controllers check
(CON.CHK)
(Master unit only)
Calculatio
n settings
Calculation mode (MODE)
(CALC)
(Master
unit only)
5-8
Setting range / set values
3 VAL (HI, GO, LO) / 2 VAL (HI or LO, INRANGE,
ALARM) / LOGIC (LOGIC, ALARM) / LOGIC2
<Default value: 3 VAL>
You can change the number of digits that appear after the
decimal point of the digital display.
0.1 / 0.01 / 0.001 / 0.0001 <Default value: 0.0001>
When the judgment value (JUDGE.V) is converted to a
current (4 to 20mA) and output as analog output, you can
set the upper limit value and lower limit value.
DEFALT (default) / FREE (free)
<Default value: DEFALT>
When analog scaling is set to "FREE", you can set the
upper limit value of scaling.
-199.9999 to 199.9999 (mm) <Default value: 10.0000>
When analog scaling is set to "FREE", you can set the
lower limit value of scaling.
-199.9999 to 199.9999 (mm) <Default value: 0.0000>
You can save power by having the backlight of the
controller display turn OFF when idle.
OFF (Eco OFF) / ON (Eco ON)<Default value: OFF>
You can set the delay count until an alarm is output.
1 to 1000 <Default value: 1000>
You can turn the pressure check ON / OFF.
ON (check ON) / OFF (check OFF)
<Regular type default value: ON>
<Air-driven type default value: OFF>
When the pressure check is set to ON, you can set the
pressure check set value.
-199.9999 to 199.9999 (mm)
<Regular 10 mm type, air-driven type default value:
10.0000>
<Regular 32 mm type default value: 32.0000>
<Regular 50 mm type default value: 50.0000>
You can turn catch check ON / OFF. The information
checked varies depending on whether the type is regular
or air-driven.
OFF (check OFF) / ON (check ON) <Default value: OFF>
When controllers are connected to the master unit, you
can check if the number connected has changed when the
power is turned ON.
OFF (check OFF) / ON (check ON) <Default value: OFF>
You can perform calculation processing based on the
measured values of each of the connected controllers,
and display the judgment result on the master unit's
display or output the judgment result from the master unit.
NO.CALC (no calculation) / CALC (calculate)
<Default value: NO.CALC>
Page
"P.
5-58
"
"P.
5-59
"
"P.
5-61
"
"P.
5-64
"
"P.
5-66
"
"P.
5-66
"
"P.
5-69
"
"P.
5-72
"
"P.
5-74
"