Setting item
HIGH set value (HI.SET)
LOW set value (LO.SET)
Hysteresis (HYSTER)
Teaching type (TEACH)
Tolerance <±> (TOL<±>)
Basic
Preset value (PR. VAL)
settings
(BASIC)
Preset data selection
(PR.OBJ)
Preset save (PR.SAVE)
Measurement direction
(DIRECT)
Lever ratio (LEVER)
5-6
Setting range / set values
You can manually set any HIGH set value (upper limit
value).
-199.9999 to -199.9999 (mm) <Default value: 5.0000>
You can manually set any LOW set value (lower limit
value).
-199.9999 to 199.9999 (mm) <Default value: 1.0000>
If the judgment value (JUDGE.V) fluctuates near the HIGH
or LOW set value, the judgment output may repeat ON /
OFF and operation may become unstable. Operation can
be stabilized by increasing the hysteresis value.
0.0000 to 199.9999 (mm) <Default value: 0.0030>
You can set the HIGH set value and LOW set value
automatically.
TCH.1 (1-point teaching) / TCH.2 (2-point teaching) /
TCH.3 (3-point teaching)
<Default value: TCH.1>
When performing 1-point teaching, you can set a value
equal to the master workpiece judgment value (JUDGE.V)
plus a tolerance as the HIGH set value, and a value equal
to the master workpiece judgment value minus a tolerance
as the LOW set value.
<Default value: 0.1000>
When performing preset, you can shift (add or subtract) to
any preset value.
-199.9999 to 199.9999 (mm) <Default value: 0.0000>
When using a preset, you can select the data (NORM.V or
JUDGE.V).
NORM.V (normal measured value) / JUDGE.V (judgment
value)
<Default value: NORM.V>
You can write preset information to EEPROM by setting
preset save to ON.
The preset ON / OFF state and offset values are saved
even when the power is turned OFF.
OFF (preset save OFF) / ON (preset save ON)
<Default value: OFF>
You can set whether the normal measured value
(NORM.V) and judgment value (JUDGE.V) are displayed
normally (plus direction) or in reverse (minus direction)
when the sensor head spindle is pressed in.
NORMAL (normal) / REVERS (reverse)
<Default value: NORMAL>
When using a lever for measurement, you can display the
measured value multiplied by the lever ratio as the
judgment value (JUDGE.V).
0.1 to 100.0
<Default value: 1.0>
Page
"P.
5-10
"
"P.
5-11
"
"P.
5-13
"
"P.
5-15
"
"P.
5-16
"
"P.
5-17
"
"P.
5-18
"
"P.
5-19
"
"P.
5-20
"
"P.
5-22
"