Panasonic HG-S Series User Manual page 175

Contact-type digital displacement sensor
Hide thumbs Also See for HG-S Series:
Table of Contents

Advertisement

Type
(Note 1)
Model No.
Resolution
Sampling cycle
Full range
Indication
accuracy
Narrow
(P-P)
range
Operation indicator
Working pressure
range
Capacity to resist
pressure
Usable fluid
Applicable tube
Protective
(Note 5)
structure
Contamination level
(Note 6)
Elevation
(Note 7)
Mechanical life
Tip deviation amount
Grounding method
Insulation resistance
Hot swap function
Ambient temperature
Ambient humidity
Vibration resistance
Shock resistance
Probe tightening
torque
Material
Weight (main unit
only)
Standards
(Note 1)
Connect an HG-S series controller (manufactured in or after February 2019).
(Note 2)
The position that represents "0" as an absolute value is a position where the spindle is pushed further
down from the bottom dead point by 0.1 mm or more. The term "stroke" indicates the total stroke
length from the bottom dead point to the top dead point.
WUME-HGS-11
General purpose
HG-S1010-AC
With a seal cap
With no seal cap
mounted
0.5μm
2.0 μm or less
1.0 μm or less (any 60 μm)
0.14 to 0.16 MPa
0.035 to 0.045 MPa
Clean air (Dew point temperature: -10°C or lower)
IP67 (IEC)
30 million times or more (Reference value)
-10 to +55 °C (No dew condensation or icing allowed), Storage: -20 to +60 °C
10 to 500 Hz with 3 mm (maximum acceleration 196 m/s
directions for two hours each
1,960 m/s
0.1 to 0.4 N⋅m (no force applied to main unit)
Body: Zinc, Holder: Stainless steel, Spindle: Tool steel, Probe: Ceramic
With a seal cap
mounted
1ms
2-color (orange / green) LED
0.14 to 0.16 MPa
0.2MPa
Outside ø4mm / Inside ø2.5mm
-
2
2,000m or lower
35 µm (typical)
Capacitor grounding
100 MΩ or higher at DC 250 V
Incorporated
35 to 85% RH, Storage: 35 to 85% RH
2
in X, Y and Z directions 3 times each
Approx. 80 g
EMC Directive/EMC Regulations
6.1 SPECIFICATIONS
High precision
HG-S1110-AC
With no seal cap
mounted
mounted
0.1μm
1.0 μm or less
0.5 μm or less (any 60 μm)
0.035 to 0.045 MPa
IP67 (IEC)
2
) amplitude in X, Y and Z
(Note 8)
-
6-7