Setting item
Response time (SPEED)
Output operation (OUTPUT)
Advanced
settings
(ADVANC)
Input all (ALL IN)
(Master unit only)
External input (EXT.IN)
External output (EXT.OUT)
WUME-HGS-11
Measurement mode
(MEAS)
Trigger mode (TRG)
Self trigger level
(SLF.LV)
Self trigger edge
direction
(SLF.EDG)
Self trigger delay
(SLF.DLY)
Static width
DLY.WD
Delay timer
(DLY.TIM)
5.1 Overview of Setting Menu
Setting range / set values
You can set the time until the judgment value (JUDGE.V)
is finalized (response time) when the sensor head starts
measurement.
3 (3 ms) / 5 (5 ms) / 10 (10 ms) / 100 (100 ms) 500 (500
ms) / 1000 (1,000 ms)
<Default value: 100>
You can select the judgment output operation.
N.O. (normal open) / N.C. (normal closed)
<Default value: N.O.>
You can select the hold mode.
S-H (sample hold) / P-H (peak hold) /
B-H (bottom hold) / P-P (peak to peak hold) / P-P/2 (peak
to peak hold / 2) / NG-H (NG hold) / SLF.S-H (self sample
hold) /
SLF.P-H (self peak hold) /
SLF.B-H (self bottom hold)
<Default value: S-H>
You can select the external trigger input action.
HOLD (hold) / 1 SHOT (one-shot)
<Default value: HOLD>
You can use the self (internal) trigger to set the criterion
level for use of the hold function.
-199.9999 to -199.9999 <Default value: 0.500>
You can use the self trigger level to set the edge direction
used to measure the hold value.
UP (rise) / DOWN (fall) <Default value: UP>
When using the self sampling hold function, you can set
the self trigger delay type.
DLY.WD (static width) / DLY.TIM (delay time)
<Default value: DLY.WD>
You can set the fluctuation width for stabilization that
triggers the start of hold.
0 to 199.9999 (mm) <Default value: 0.0100>
You can set a delay time for the start of hold.
0 to 9999 (mm) <Default value: 1000>
You can enable ALL IN on the master unit to input trigger
input, preset input, and other signals into all connected
slave units.
ONE (single) / ALL (all)<Default value: ONE>
You can select from four combinations for the signals that
are input into input 1 / input 2 / input 3 of external input.
P/R/T (preset / reset / trigger) /
BANK/P (bank A, B / preset) / BANK/R (bank A, B /
reset) / BANK/T (bank A, B / trigger)
<Default value: P/R/T>
You can select from four combinations for the signals that
are output into output 1 / output 2 / output 3 of external
output.
Page
"P.
5-23
"
"P.
5-24
"
"P.
5-26
"
"P.
5-28
"
"P.
5-41
"
"P.
5-41
"
"P.
5-41
"
"P.
5-51
"
"P.
5-53
"
"P.
5-55
"