Self Sample Hold (Static Width)
The normal measured value (NORM.V) can be held automatically as the judgment value
(JUDGE.V) when the measured value becomes less than the specified static width (within the
fluctuation stabilization interval) after the specified self trigger level is exceeded.
Timing chart
1. After the measurement value drops below the static width (fluctuation stabilizes), the
previous value is held until the response time elapses.
(When the power is turned ON, the indeterminate state is held.)
2. After holding starts, the normal measured value (NORM.V) is held as the judgment value
(JUDGE.V) until the next self trigger action.
3. During the sampling interval, the judgment value (JUDGE.V) is held while all judgment
outputs turn OFF.
4. Before entering the static width, an alarm state occurs if the normal measured value
(NORM.V) falls below the self trigger level. (When the self trigger edge direction is "UP".)
WUME-HGS-11