External Output - Panasonic HG-S Series User Manual

Contact-type digital displacement sensor
Hide thumbs Also See for HG-S Series:
Table of Contents

Advertisement

Setting method
Setting item
External input (EXT.IN)

5.3.4 External Output (

You can select from four combinations for the signals that are output into output 1 / output 2 /
output 3 of external output.
This product has an alarm signal output function. Alarm signals enable prompt action when the
sensor head is not operating correctly.
When "3-value (3 VAL)" is selected, the alarm outputs a HIGH judgment value and a LOW
judgment value.
"Logic 2 (LOGIC2)" is output from the master unit as a judgment value (JUDGE.V) that
indicates the output logic calculation result when slave units are connected.
WUME-HGS-11
Set values
Preset / Reset / Trigger (P/R/T)
Bank A / Bank B / Preset (BANK/P)
Bank A / Bank B / Reset (BANK/R)
Bank A / Bank B / Trigger (BANK/T)
)
5.3 Advanced Settings (
)
Default value
P/R/T
5-55

Advertisement

Table of Contents
loading

Table of Contents