● This application can only be selected when at least two slave units are connected.
■
Thickness (
This function calculates thickness by pressing on both sides of the measured object with two
sensor heads.
Calculated value = Measured value of master unit + Measured value of slave unit 1
● The slave unit closest to the master unit does not output a judgment result. (Always OFF)
If two or more slave units are connected, the 2nd and subsequent slave units perform normal
judgment without calculation.
● The sensor head indicator of the slave unit closest to the master unit shows the judgment
result of the master unit.
● The response time for judgment output from the master unit is the response time setting on
the master unit and slave units plus 3 ms.
● This application can only be selected when at least one slave unit is connected.
WUME-HGS-11
5.4 Calculation Settings (
)
) (Master Unit Only)
5-81