Measurement mode
(MEAS)
Sample hold (S-H)
Peak hold (P-H)
Bottom hold (B-H)
Peak to peak hold (P-
P)
Peak to peak hold / 2
(P-P/2)
NG hold (NG-H)
Self sample hold
(SLF.S-H)
Self peak hold
(SLF.P-H)
Self bottom hold
(SLF.B-H)
● When the calculation application selection function is set to "STAND" (standard difference), the
hold setting on the master unit is invalid.
● Depending on the calculation application selection setting, the hold setting on the slave unit
used for calculation may be invalid.
Sample Hold
External trigger input ON holds the judgment value (JUDGE.V). External trigger input OFF
releases the hold state and the value is updated whenever necessary.
The hold action can be changed with the trigger mode setting.
WUME-HGS-11
Function
Perform hold output of judgment value
(JUDGE.V) only when external input is
ON.
When external input is OFF, update
judgment value (JUDGE.V) whenever
necessary and output. (Real-time output)
Perform hold output of maximum value as
judgment value (JUDGE.V).
Perform hold output of minimum value as
judgment value (JUDGE.V).
Perform hold output of difference between
maximum value and minimum value as
judgment value (JUDGE.V).
Perform hold output of one-half of
difference between maximum value and
minimum value as judgment value
(JUDGE.V).
Hold LOW judgment and HIGH judgment
output.
Perform automatic hold
output of judgment value
Delay timer
(JUDGE.V) by self
trigger after delay
elapses.
Perform automatic hold
output of judgment value
(JUDGE.V) by self
Static width
trigger after
measurement fluctuation
stabilizes.
Perform automatic hold output by self
trigger of maximum value as judgment
value (JUDGE.V).
Perform automatic hold output by self
trigger of minimum value as judgment
value (JUDGE.V).
5.3 Advanced Settings (
External
trigger input
Valid
"Sample Hold"
Valid
Valid
"Peak Hold, Bottom Hold,
Peak to Peak Hold, Peak to
Valid
Peak Hold / 2"
Valid
Valid
"NG hold"
Invalid
"Self Sample Hold (Delay
(Use self
Timer)"
trigger)
Invalid
"Self Sample Hold (Static
(Use self
Width)"
trigger)
Invalid
(Use self
trigger)
"Self Peak Hold / Self
Bottom Hold"
Invalid
(Use self
trigger)
)
Section
5-27