5.3 Advanced Settings (
Timing chart
1. When the power is turned ON, the indeterminate state is held until the external trigger
input turns ON.
2. When the external trigger input turns ON (rising edge), the minimum normal measured
value (NORM.V) that occurs during the sampling interval is held as the judgment value
(JUDGE.V).
3. If the reset input turns ON, the indeterminate state is held.
4. Judgment output outputs the judgment result based on the output setting.
* When the calculation function is used, calculation value "CALC" is shown instead of normal
measured value (NORM.V).
Peak to Peak Hold (Trigger mode: One-shot)
With respect to normal measured values (NORM.V) during any sampling interval, the difference
between the peak value (maximum value) and the bottom value (minimum value) is held as the
judgment value (JUDGE.V). The judgment value (JUDGE.V) is updated and held each time the
external trigger input turns ON (rising edge).