Panasonic HG-S Series User Manual page 100

Contact-type digital displacement sensor
Hide thumbs Also See for HG-S Series:
Table of Contents

Advertisement

5.3 Advanced Settings (
For input signal combinations, see
Sample Hold (Trigger mode: Hold)
Hold while external trigger input is ON.
Timing chart
1. The judgment value (JUDGE.V) is held while the external trigger input is ON.
2. If the reset input turns ON while the external trigger input is ON, the indeterminate state is
held.
3. Judgment output outputs the judgment result based on the output setting.
* When the calculation function is used, calculation value "CALC" is shown instead of normal
measured value (NORM.V).
Sample Hold (Trigger mode: One-shot)
Hold is refreshed each time the external trigger input turns ON (rising edge).
5-28
)
"5.3.3 External Input (
)".
WUME-HGS-11