Timing chart
1. When the power is turned ON, the indeterminate state is held until the external trigger
input turns ON.
2. When the external trigger input turns ON (rising edge), the difference between the
minimum value (B1)and maximum value (P1)of normal measured values (NORM.V) that
occur during the sampling interval is held as the judgment value (JUDGE.V).
3. If the reset input turns ON, the indeterminate state is held.
4. Judgment output outputs the judgment result based on the output setting.
* When the calculation function is used, calculation value "CALC" is shown instead of normal
measured value (NORM.V).
Peak to Peak Hold / 2 (Trigger mode: One-shot)
With respect to normal measured values (NORM.V) during any sampling interval, half the
difference between the peak value (maximum value) and the bottom value (minimum value) is
held as the judgment value (JUDGE.V). The judgment value (JUDGE.V) is updated and held
each time the external trigger input turns ON (rising edge).