Statuses And Measures - Panasonic HG-S Series User Manual

Contact-type digital displacement sensor
Hide thumbs Also See for HG-S Series:
Table of Contents

Advertisement

4.3.2 Statuses and Measures

The statuses judged by the self-monitoring function are classified into the following four
categories.
When the status is "notification", "caution", or "fault", you must check the installation state or
maintain or replace the product.
Status
Normal
Normal state
Notification
Unstable detection state
Caution
State in which the device must be replaced
Abnormal
State in which the device is uncontrollable
If "notification", "caution", or "fault" status is displayed, take measures as shown in the following
table.
This product does not have "Caution" information.
Response parameter
Sensor head unconnected
Connected unit count check error
NPN / PNP output types mixture
error
Calculated unlit count error
Notifi
cation
Copying was executed but it failed
because the slave unit was
abnormal
The thrust on the sensor head
stroke is above the specified range.
Pressure check
Catch check
Controller memory function
damaged
Sensor head memory function
damaged
Abnor
Output section short-circuit error
mal
Detection circuit damaged
System error
(Note 1)
Error codes and measurement alarms are displayed on HG-SC□ controllers.
● For details on how to read each status, refer to the user's manual of the communication unit
SC-HG1 series (except the SC-HG1-USB) that you use.
WUME-HGS-11
Description
Measures
Status check
Status check
Status check
Status check
Status check
Status check
Status check
Status check
Controller
replacement
Sensor head
replacement
Status check /
Replacement
Sensor head
replacement
Controller
replacement
4.3 Self-monitoring Function
Remarks
The device is operating normally.
Review the settings.
The device has almost reached its service life.
The device is short-circuited or broken.
(Note 1)
Error code
E200
E160 (For master
units only)
E100 (For master
units only)
E110(For master
units only)
E170(For master
units only)
E210
E600 / E610 / E620
E630
E700
E240
E900 / E910 / E911 /
E912 / E920
(Note 1)
Alarm
Alarm
Alarm
4-23