Panasonic HG-S Series User Manual page 114

Contact-type digital displacement sensor
Hide thumbs Also See for HG-S Series:
Table of Contents

Advertisement

5.3 Advanced Settings (
Timing chart
1. The previous value is held until the delay time elapses. (When the power is turned ON, the
indeterminate state is held.)
2. After the delay time elapses, the normal measured value (NORM.V) is held as the
judgment value (JUDGE.V) until the next self trigger action.
3. During the delay time, the judgment value (JUDGE.V) is held while all judgment outputs
turn OFF.
4. Before the delay time elapses, an alarm state occurs if the normal measured value
(NORM.V) falls below the self trigger level. (When the self trigger edge direction is "UP".)
5. If the reset input turns ON, the indeterminate state is held. If this occurs during the delay
time, the delay time ends.
6. Judgment output outputs the judgment result based on the output setting.
* When the calculation function is used, calculation value "CALC" is shown instead of normal
measured value (NORM.V).
5-42
)
WUME-HGS-11

Advertisement

Table of Contents
loading

Table of Contents