Self Peak Hold (Trigger mode: One-shot)
After the end of self trigger, the peak value during the sampling interval (the interval from the
end to the start of self trigger) is held as the judgment value (JUDGE.V).
When self trigger starts, the next sampling interval starts.
Self trigger starts when the value rises above (falls below) the self trigger level.
Self trigger ends when the value falls below (rises above) the self trigger level.
Timing chart
1. When the power is turned ON, the indeterminate state is held until self trigger ends.
2. When self trigger ends, the maximum normal measured value (NORM.V) that occurs
during the sampling interval is held as the judgment value (JUDGE.V).
3. The previous value is held from the start of self trigger to the end (sampling interval).
4. If the reset input turns ON, the indeterminate state is held. If within the sampling interval,
the sampling interval ends.
5. Judgment output outputs the judgment result based on the output setting.
● When self peak hold or self bottom hold is selected, external trigger input is invalid.
● When a sensor head not connected error or pressure alarm / error is cleared, the same action
as a reset takes place.
● The judgment value (JUDGE.V) is held in the same way in the measurement modes of self
bottom hold.