3.3 Wiring the Controller Connector on the Sensor Head Connection Cable
3.
Insert the wire firmly into the wire insertion hole. Make sure that the jacketed part of the wire
has entered the wire insertion hole and the tips of the core wires have passed through the
connection part as shown below.
4.
Insert the tip of the flat-head screwdriver into the release hole so that it contacts the bottom
of the lever (white), and move the tip of the flat-head screwdriver up. The lever (white) will
make a "click" sound when it returns to its original position, and the wire will be locked.
5.
Pull on the wire gently to ensure that it does not come out.
6.
Slide the protective cover in the direction of the arrow to return the cover to its original
position.
WUME-HGS-11
Terminal No.
1
2
3
4
5
6
Connection cable
Red
White
Green
Black
3-7