Panasonic HG-S Series User Manual page 86

Contact-type digital displacement sensor
Hide thumbs Also See for HG-S Series:
Table of Contents

Advertisement

5.2 Basic Settings (
● Set the hysteresis to a value that is smaller than the difference between the HIGH set value
and the LOW set value. If the hysteresis is set to a value that is larger than the difference
between the HIGH set value and the LOW set value, a GO judgment will not be output.
● Even when a hysteresis is set, always set a HIGH set value that is higher than the LOW set
value. If the LOW set value is higher than the HIGH set value, a GO judgment will not be
output.
Setting method
Setting item
Hysteresis (HYSTER)
5-14
)
Setting range
0 to 199.9999 (mm)
Default value
0.0030
WUME-HGS-11

Advertisement

Table of Contents
loading