3.5 Connecting Controllers

● Always shut OFF the power before connecting a slave unit to or disconnecting a slave
unit from the master unit. Risk of controller damage if you attempt connection or removal
with the power ON.
● Insert the male connector firmly into the female connector. Risk of controller damage if
not completely connected.
● When connecting slave units to a master unit, connect only NPN output types, or only
PNP output types. Dissimilar output types cannot be connected together.
● An HG-SC series controller manufactured in January 2019 or earlier cannot be used
together with an HG-TC series controller. To use these controllers together, use an HG-
SC series controller manufactured in February 2019 or later.
● To connect units, the units must be mounted on a DIN rail. Attach end plates MS-DIN-E
(optional) so as to enclose the connected units at the ends.