Teaching Types - Panasonic HG-S Series User Manual

Contact-type digital displacement sensor
Hide thumbs Also See for HG-S Series:
Table of Contents

Advertisement

5.2.4 Teaching Types (

You can set the HIGH set value and LOW set value automatically.
For the teaching method, you can select from "1-point teaching", "2-point teaching", or "3-point
teaching".
Teaching type
1-point teaching
2-point teaching
3-point teaching
WUME-HGS-11
)
You can use a master workpiece to automatically set upper and lower
limit values.
Use this method when you want to judge workpieces by a ± tolerance.
(Note 1)
When the tolerance (±) is set to 1.0000
You can use two workpieces to automatically set upper and lower limit
values.
Use this method when you want to judge workpieces within an upper limit
and lower limit range.
You can use a good workpiece, a HIGH-side defective workpiece, and a
LOW-side defective workpiece to automatically set upper and lower limit
values.
Use this method when you want to judge workpieces within a range that
takes the intermediate values between good and defective workpieces as
upper and lower limits.
5.2 Basic Settings (
Function
)
Factory
default state
Default state
5-15